HADCORP

Home

Implant Research

Dr Ostermeyer's Research

Neoplasms & Implants

Platinum Testing

Children and Silicone

About Breast Implants

Alternative Implants

Suicide and Implants

Implants and the FDA

Implants in the UK

Silicone Immune Protocol

Biotoxins

MCS

Implant Identification

Implant Photos

Orthopaedic Implants

Board of Directors

Medical Device News

Glossary

Implant Resources

Contact Us

Members
 

Knowledge Empowers   


Anal Chem. 1997 Dec 1;69(23):4912-6.

Release of low molecular weight silicones and platinum from silicone breast implants.

·         Lykissa ED,

·         Kala SV,

·         Hurley JB,

·         Lebovitz RM.

 

Department of Pathology, Baylor College of Medicine, Houston, Texas 77030, USA.

 

We have conducted a series of studies addressing the chemical composition of silicone gels from breast implants as well as the diffusion of low molecular weight silicones (LM-silicones) and heavy metals from intact implants into various surrounding media, namely, lipid-rich medium (soy oil), aqueous tissue culture medium (modified Dulbecco's medium, DMEM), or an emulsion consisting of DMEM plus 10% soy oil. LM-silicones in both implants and surrounding media were detected and quantitated using gas chromatography (GC) coupled with atomic emission (GC-AED) as well as mass spectrometric (GC/MS) detectors, which can detect silicones in the nanogram range. Platinum, a catalyst used in the preparation of silicone gels, was detected and quantitated using inductive argon-coupled plasma/mass spectrometry (ICP-MS), which can detect platinum in the parts per trillion range. Our results indicate that GC-detectable low molecular weight silicones contribute approximately 1-2% to the total gel mass and consist predominantly of cyclic and linear poly-(dimethylsiloxanes) ranging from 3 to 20 siloxane [(CH3)2-Si-O] units (molecular weight 200-1500). Platinum can be detected in implant gels at levels of approximately 700 micrograms/kg by ICP-MS. The major component of implant gels appears to be high molecular weight silicone polymers (HM-silicones) too large to be detected by GC. However, these HM-silicones can be converted almost quantitatively (80% by mass) to LM-silicones by heating implant gels at 150-180 degrees C for several hours. We also studied the rates at which LM-silicones and platinum leak through the intact implant outer shell into the surrounding media under a variety of conditions. Leakage of silicones was greatest when the surrounding medium was lipid-rich, and up to 10 mg/day LM-silicones was observed to diffuse into a lipid-rich medium per 250 g of implant at 37 degrees C. This rate of leakage was maintained over a 7-day experimental period. Similarly, platinum was also observed to leak through intact implants into lipid-containing media at rates of approximately 20-25 micrograms/day/250 g of implant at 37 degrees C. The rates at which both LM-silicones and platinum have been observed to leak from intact implants could lead to significant accumulation within lipid-rich tissues and should be investigated more fully in vivo.





Platinum Testing

 

The information on this website is presented for educational purposes by the Human Adjuvant Disease Corp.